Specifications

3-18 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
807-The Setup
password is
cleared. Please
power off and
restore the clear
password switch
(SW1.1)
None System board
configuration switch
SW1.1 has been
turned on and the
system configuration
password has been
cleared. SW1.1 must
be returned to the
default Off position
for normal operation
and the ability to set
a password with the
server setup utility.
1. Remove power from the system.
2. Locate the system board
configuration switch.
3. Return SW1.1 to the Off position.
4. Restart the system.
5. Press F10 and use the server
setup utility to set a new
password.
1151-Com Port 1
Address
Assignment
Conflict.
2 short Both external and
internal serial ports
are assigned to
COM1.
Run the server setup utility and correct.
1151-Serial Port A
Address Conflict
Detected
2 short Hardware conflict is
preventing the
normal operation of
a serial port.
Run the server setup utility to reassign
the serial port address and manually
resolve the conflict.
1152-Com Port 2,
3, or 4 Address
Assignment
Conflict.
2 short Both external and
internal serial ports
are assigned to
COM2, COM3, or
COM4.
Run the server setup utility and correct.
1152-Serial Port B
Address Conflict
Detected
2 short Hardware conflict is
preventing the
normal operation of
a serial port.
Run the server setup utility to reassign
the serial port address and manually
resolve the conflict.
1155-Serial Port
Address Conflict
Detected
2 short Hardware conflict is
preventing the
normal operation of
a serial port.
Run the server setup utility to reassign
the serial port address and manually
resolve the conflict.
1610-Temperature
violation detected.
Waiting for system
to cool
2 short Ambient system
temperature too hot.
Check fan and system environment.
continued