Specifications
3-16 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
802-Processor X
is missing or
terminator board
is not present.
System Halted.
None System detected that
the indicated
processor slot is
empty.
1. Verify that a processor or
processor terminator board is
installed in each processor slot.
2. Reseat the processor or processor
terminator board in each
processor slot.
3. Verify that each processor has a
corresponding PPM installed.
4. Try replacing each processor with
a processor terminator board to
detect a failed processor or PPM.
803-Processor
speeds must
match for system
operation. System
Halted
None Two processors with
different speed
ratings are installed
in the system.
All installed
processors must
have the same speed
rating for safe
operation.
1. Replace one of the processors
with a processor terminator card.
2. Replace one of the processors
with an alternate processor rated
for the same operating speed as
the installed processor.
804-100MHz
memory is
incompatible.
System Halted
None A memory module
other than 133-MHz
ECC SDRAM DIMM
has been detected.
1. Reseat all memory modules in the
system.
2. Remove incompatible memory
modules.
3. Sequentially try each memory
module in DIMM slot 1 to identify
the incompatible memory module.
continued