Specifications

Diagnostics and Troubleshooting 3-11
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
207-Invalid
Memory
Configuration
Check DIMM
Installation
None Memory module
installed incorrectly.
Verify placement of memory modules.
208-Invalid
Memory Speed
Check DIMM
Installation
1 long, 1 short Speed of the
memory is not
compatible.
Verify the speed of the memory
modules installed, then check the
server user documentation and replace
as indicated.
209-Memory
Detection Failure.
Check Memory
Installation
1 long, 1 short Unable to size
memory.
Check memory module installation and
if error persists, call Compaq authorized
service provider.
211-Invalid
Voltage Regulator
Module installed
for Processor X
None Nonredundant PPM
installed in indicated
processor slot.
Replace with a PPM that supports
redundancy.
212-System
Processor
Failed/Mapped out
1 short Processor in slot X
failed.
Run Diagnostics and replace failed
processor.
214-DC-DC
Converter Failed
None PPM failed. Run Diagnostics. Replace failed
assembly as indicated.
214-Memory
Device Failure.
Error Code:X
Memory Module
DIMM:Y
2 short A memory module
has failed.
Run Diagnostics. Replace failed
memory module as indicated.
214-Processor
PPM Failed,
Module X
None Indicated PPM failed. Replace failed assembly as indicated.
215-Processor
Power Module has
lost Redundancy
in Socket X
None PPM (DC-DC
converter) has lost
redundancy.
Run Diagnostics. Replace failed
assembly as indicated.
continued