Specifications

3-10 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
174-
Configuration/Slot
Mismatch Device
Not Found
None EISA or PCI board not
found.
Run the server setup utility and correct.
175-
Configuration/Slot
Mismatch Device
Found
None EISA or PCI board
added, configuration
not updated.
Run the server setup utility and correct.
177-Configuration
Not Complete
None Incomplete System
Configuration
detected.
Run the server setup utility and correct.
178-Processor
Configuration
Invalid
None Processor type or
step does not match
configuration
memory.
Run the server setup utility and correct.
180-Log
Reinitialized
None The IML has been
reinitialized, probably
due to corruption of
the log.
Event message, no action required.
201-Memory Error None RAM failure
detected.
Run Diagnostics. Replace failed
assembly as indicated.
202-Memory Type
Mismatch
2 short An incompatible
memory module is
installed in the
system.
Compare Compaq part numbers from
installed memory modules with the
manual.
If not listed, the memory modules are
incompatible and should be replaced or
removed.
203-Memory
Address Error
None RAM failure
detected.
Run Diagnostics. Replace failed
assembly as indicated.
207-ECC
Corrected Single
Bit Errors in DIMM
in Memory Module
Socket
2 short A memory module is
malfunctioning.
Run Diagnostics. Replace or remove
malfunctioning memory module as
indicated.
continued