Specifications
Diagnostics and Troubleshooting  3-7 
Table 3-2 
POST Error Messages 
Error Code  Audible Beeps  Probable Source of 
Problem 
Action 
A Correctable 
Memory Error 
occurred prior to 
this power up 
None  A memory module 
has experienced an 
error that, while 
recoverable, has 
generated a 
predictive failure 
warning. 
Run Diagnostics to identify the failed 
memory module, and then replace it. 
A Critical Error 
occurred prior to 
this power up 
None A catastrophic 
system error, which 
caused the server to 
crash, has been 
logged. 
Run Diagnostics. Replace failed 
assembly as indicated. 
Beeps only  2 long  No valid memory is 
present in the 
system. 
1.  If no memory modules are 
present, install at least one 
memory module to conform to 
minimum hardware configuration 
specifications. 
2.  Reseat all installed memory 
modules. 
3.  If the system contains more than 
one memory module, remove one 
module, and restart the server, 
repeating as needed to isolate the 
bad memory module. 
Beeps only  2 long, 2 short  The power has 
cycled because the 
temperature is too 
hot. The processor 
fan is not installed, 
or is not spinning.  
Check fans. 
Critical Fan Failure 
Detected – 
System Shutting 
Down 
System Halted 
None  A critical fan is not 
spinning. 
1. Check fans. 
2.  Check fan cable connections. 
continued 