Diagnostics and Troubleshooting 3-75
4. Insert the ROMPaq diskette. Although you use a normal ROMPaq diskette, this situation
does not allow you to save the old image.
5. Power up the server. The keyboard, mouse, and monitor are all inactive.
6. The server makes two long beeps to indicate that you are in Disaster Recovery Mode and
that you should insert the ROMPaq diskette.
7. The server reads the diskette for the latest ROM image. If the diskette is not in place, the
system continues to beep until a valid ROMPaq diskette is inserted.
8. The ROMPaq diskette flashes the system ROM.
9. A series of increasing tones indicates disaster recovery is complete and successful.
10. A series of decreasing tones indicates disaster recovery has failed.
11. After successful completion of this process,
a. Power down the server
b. Restore System BIOS SW1 Configuration Switch to its normal position.
c. Power up the server as usual.
After a failed ROMPaq, power down the server and repeat the above process.