Specifications
3-72  Compaq ProLiant ML350 Maintenance and Service Guide 
Table 3-22 
ASR IML Messages 
continued 
Message Description 
NMI – Fail-Safe Timer 
Expiration 
Software was unable to reset the system fail-safe timer, resulting in a 
server failure. 
Processor Exception  The indicated processor exception occurred. 
NMI – Processor Parity Error  The processor detected a data error, resulting in a server failure. 
NMI – Software Generated 
Interrupt Detected Error 
Software indicated a system error, resulting in a server failure. 
Caution: Temperature Exceeded  The operating system has detected that the temperature of the system has 
exceeded the caution level. Accompanying data in the log notes whether 
an auto-shutdown sequence has been invoked by the operating system. 
Abnormal Program Termination  The operating system has encountered an abnormal situation that has 
caused a system failure. 
ASR Test Event  A test program caused ASR. 
NMI – Automatic Server 
Recovery Timer Expiration 
The operating system has received notice of an impending ASR timer 
expiration. 
Required System Fan Failure  The required system fan has failed. Accompanying data in the log notes if 
an auto-shutdown sequence has been invoked by the operating system. 
UPS A/C Line Failure Shutdown 
or Battery Low 
The UPS notified the operating system that the AC power line has failed. 
Accompanying data indicates whether either an auto-shutdown sequence 
has been invoked or the battery is nearly depleted. 
ASR detected by ROM  An ASR activity has been detected and logged by the system ROM. 