Specifications
Diagnostics and Troubleshooting  3-71 
ASR Integrated Management Log (IML) Messages 
The Integrated Management Log (IML) records memory errors, as well as catastrophic 
hardware and software errors, that cause the system to fail. This information helps you quickly 
identify and correct the problem, thus minimizing downtime. 
You can view the IML through Compaq Insight Manager. The Diagnostics Utility either 
resolves the error or suggests corrective action in systems that do not support event logs. 
The IML identifies and records all the errors in Table 3-22. 
Table 3-22 
ASR IML Messages 
Message Description 
Abnormal Program Termination  The operating system has encountered an abnormal situation that has 
caused a system failure. 
ASR detected by ROM  An ASR activity has been detected and logged by the system ROM. 
ASR Test Event  The System Configuration Utility generated a test alert. 
Automatic Server Recovery 
Base Memory Parity Error 
The system detected a data error in base memory following a reset due to 
the Automatic Server Recovery (ASR) timer expiration. 
Automatic Server Recovery 
Memory Parity Error 
Corrupt system memory caused the OS to crash. Run Diagnostics to 
identify the failed DIMM. 
Battery Failing  Low system battery warning. Replace battery within 7 days to prevent loss 
of nonvolatile configuration memory. Failure of the battery supporting the 
nonvolatile RAM in the system is imminent. 
Caution: Temperature Exceeded  The operating system has detected that the temperature of the system has 
exceeded the caution level. Accompanying data in the log notes if an 
auto-shutdown sequence has been invoked by the operating system. 
Diagnostic Error  An error was detected by the Diagnostics Utility. See the specific error code 
in this chapter for a detailed explanation. 
Error Detected On Boot Up  The server detected an error during POST. 
Processor Prefailure  A CPU has passed an internal corrected error threshold; excessive internal 
ECC cache errors. 
NMI – PCI Bus Parity Error  A parity error was detected on the PCI bus. 
NMI – Expansion Board Error  A board on the expansion bus indicated an error condition, resulting in a 
server failure. 
NMI – Expansion Bus Master 
Time-Out 
A bus master expansion board in the indicated slot did not release the bus 
after its maximum time, resulting in a server failure. 
NMI – Expansion Bus Slave 
Time-Out 
A board on the expansion bus delayed a bus cycle beyond the maximum 
time, resulting in a server failure. 
continued 