Diagnostics and Troubleshooting 3-65
Event List
The Event List displays the affected components and the associated error messages. Though the
same basic information displays, the format of the list may differ, depending on how you view
it: on the IMD, from within Compaq Insight Manager, or the Compaq Survey Utility. An
example of the format of an event displayed on the IMD as follows:
**001 of 010**
---caution---
03/19/1997
12:54 PM
FAN INSERTED
Main System
Location:
System Board
Fan ID: 03
**END OF EVENT**
Event Messages
Table 3-20
Event Messages
Event Type Event Message Action
Machine Environment
Fan Failure System Fan Failure (Fan X, Location). Replace fan.
Fan Inserted System Fan Inserted (Fan X, Location). None
Fan Removed System Fan Removed (Fan X, Location). None
Fans Not Redundant System Fans Not Redundant. Add fan.
Overheat Condition System Overheating (Zone X, Location). Check fans.
Main Memory
Correctable Error
threshold exceeded
Corrected Memory Error threshold passed
(Slot X, Memory Module X).
Replace the defective memory
module.
Corrected Memory Error threshold passed
(System Memory).
Replace memory modules one at a
time (if more than one) and retest
the system after each replacement.
Corrected Memory Error threshold passed
(Memory Module unknown).
Replace the memory modules one
at a time (if more than one).
Uncorrectable Error Uncorrectable Memory Error (Slot X,
Memory Module X).
Replace the defective memory
module.
Uncorrectable Memory Error (System
Memory).
Replace the defective memory
module.
Uncorrectable Memory Error (Memory
Module unknown).
Replace memory modules one at a
time (if more than one) and retest
the system after each replacement.
continued