Specifications
Diagnostics and Troubleshooting  3-65 
Event List 
The Event List displays the affected components and the associated error messages. Though the 
same basic information displays, the format of the list may differ, depending on how you view 
it: on the IMD, from within Compaq Insight Manager, or the Compaq Survey Utility. An 
example of the format of an event displayed on the IMD as follows: 
**001 of 010** 
---caution--- 
03/19/1997 
12:54 PM 
FAN INSERTED 
Main System 
Location: 
 System Board 
Fan ID: 03 
**END OF EVENT** 
Event Messages 
Table 3-20 
Event Messages 
Event Type  Event Message  Action 
Machine Environment 
Fan Failure  System Fan Failure (Fan X, Location).  Replace fan. 
Fan Inserted  System Fan Inserted (Fan X, Location).  None 
Fan Removed  System Fan Removed (Fan X, Location).  None 
Fans Not Redundant  System Fans Not Redundant.  Add fan. 
Overheat Condition  System Overheating (Zone X, Location).  Check fans. 
Main Memory 
Correctable Error 
threshold exceeded 
Corrected Memory Error threshold passed 
(Slot X, Memory Module X). 
Replace the defective memory 
module. 
  Corrected Memory Error threshold passed 
(System Memory). 
Replace memory modules one at a 
time (if more than one) and retest 
the system after each replacement. 
  Corrected Memory Error threshold passed 
(Memory Module unknown). 
Replace the memory modules one 
at a time (if more than one). 
Uncorrectable Error  Uncorrectable Memory Error (Slot X, 
Memory Module X). 
Replace the defective memory 
module. 
  Uncorrectable Memory Error (System 
Memory). 
Replace the defective memory 
module. 
  Uncorrectable Memory Error (Memory 
Module unknown). 
Replace memory modules one at a 
time (if more than one) and retest 
the system after each replacement. 
continued 










