Specifications
3-60  Compaq ProLiant ML350 Maintenance and Service Guide 
Table 3-19 
ADU Diagnostic Messages 
continued 
Message Description  Recommended Action 
Loose cable 
detected – 
logical drives 
may be marked 
FAILED until 
corrected 
Controller unable to communicate 
with one or more physical drives, 
probably because of a cabling 
problem. Logical drives may be in a 
FAILED state until the condition is 
corrected, preventing access to data 
on the controller. 
Check all controller and drive cable 
connections. 
Mirror data 
miscompare 
Data was found at reinitialization in 
the posted write memory; however, 
the mirror data compare test failed 
resulting in data being marked as 
invalid. Data loss is possible. 
Replace the array accelerator board. 
No configuration 
for accelerator 
board 
Array accelerator board has not been 
configured. 
If the array accelerator board is present, run the 
Array Configuration Utility (ACU) to configure the 
board. 
NVRAM 
configuration 
present, 
controller not 
detected 
EISA nonvolatile RAM has a 
configuration for an array controller, 
but there is no board in this slot. 
Either a board has been removed 
from the system or a board has been 
placed in the wrong slot. 
Place the array controller in the proper slot or 
run the BIOS Setup Utility to reconfigure 
nonvolatile RAM to reflect the removal or new 
position. 
RIS copies 
between drives 
do not match 
Drives on controller contain copies of 
RIS that do not match. 
Upgrade ADU to the most recent version. 
SCSI Port x Drive 
ID x has 
exceeded 
threshold(s) 
Monitor and performance threshold 
for this drive has been violated. 
Check for the particular threshold that has been 
violated. 
SCSI Port x Drive 
ID x is not 
stamped for 
monitoring 
Drive has not been stamped with 
Monitor and Performance features. 
Run the Array Configuration Utility (ACU). 
Changing the configuration and saving should 
cause ACU to stamp drive with Monitor and 
Performance features. To do this without 
destroying the current configuration, change 
array accelerator size and save configuration. 
Change the array accelerator back to original 
size and save again. 
SCSI Port x Drive 
ID x RIS copy 
mismatch 
Copies of RIS on drive do not match.  Drive may need to be replaced. Check for other 
errors. 
SCSI Port x Drive 
ID x failed – 
REPLACE (failure 
message) 
ADU found drive that needs to be 
replaced. 
Replace drive or correct condition that caused 
error. 
SCSI Port x Drive 
ID x firmware 
needs upgrading 
Drive firmware is below 
recommended version. 
Run Options ROMPaq Utility to upgrade drive to 
latest firmware revision. 
continued 