Specifications

3-60 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-19
ADU Diagnostic Messages
continued
Message Description Recommended Action
Loose cable
detected
logical drives
may be marked
FAILED until
corrected
Controller unable to communicate
with one or more physical drives,
probably because of a cabling
problem. Logical drives may be in a
FAILED state until the condition is
corrected, preventing access to data
on the controller.
Check all controller and drive cable
connections.
Mirror data
miscompare
Data was found at reinitialization in
the posted write memory; however,
the mirror data compare test failed
resulting in data being marked as
invalid. Data loss is possible.
Replace the array accelerator board.
No configuration
for accelerator
board
Array accelerator board has not been
configured.
If the array accelerator board is present, run the
Array Configuration Utility (ACU) to configure the
board.
NVRAM
configuration
present,
controller not
detected
EISA nonvolatile RAM has a
configuration for an array controller,
but there is no board in this slot.
Either a board has been removed
from the system or a board has been
placed in the wrong slot.
Place the array controller in the proper slot or
run the BIOS Setup Utility to reconfigure
nonvolatile RAM to reflect the removal or new
position.
RIS copies
between drives
do not match
Drives on controller contain copies of
RIS that do not match.
Upgrade ADU to the most recent version.
SCSI Port x Drive
ID x has
exceeded
threshold(s)
Monitor and performance threshold
for this drive has been violated.
Check for the particular threshold that has been
violated.
SCSI Port x Drive
ID x is not
stamped for
monitoring
Drive has not been stamped with
Monitor and Performance features.
Run the Array Configuration Utility (ACU).
Changing the configuration and saving should
cause ACU to stamp drive with Monitor and
Performance features. To do this without
destroying the current configuration, change
array accelerator size and save configuration.
Change the array accelerator back to original
size and save again.
SCSI Port x Drive
ID x RIS copy
mismatch
Copies of RIS on drive do not match. Drive may need to be replaced. Check for other
errors.
SCSI Port x Drive
ID x failed
REPLACE (failure
message)
ADU found drive that needs to be
replaced.
Replace drive or correct condition that caused
error.
SCSI Port x Drive
ID x firmware
needs upgrading
Drive firmware is below
recommended version.
Run Options ROMPaq Utility to upgrade drive to
latest firmware revision.
continued