Specifications

3-56 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-19
ADU Diagnostic Messages
continued
Message Description Recommended Action
Controller is not
configured
Controller is not configured. If
controller was previously configured
and you change drive locations, there
may be a problem with placement of
the drives. ADU examines each
physical drive and looks for drives
that have been moved to a different
drive bay.
Look for messages indicating which drives have
been moved. If none displays and drive
swapping did not occur, run the Array
Configuration Utility (ACU) to configure the
controller and run the BIOS Setup Utility to
configure nonvolatile RAM. Do not run either
utility if you believe drive swapping has
occurred.
Controller
reported POST
error.
Error Code: x
The controller returned an error from
its internal POSTs.
Replace the controller.
Controller
restarted with a
signature of zero
ADU did not find a valid configuration
signature to use to get the data.
Nonvolatile RAM may not be present
(unconfigured) or the signature
present in nonvolatile RAM may not
match the signature on the
controller.
Run the BIOS Setup Utility to configure the
controller and nonvolatile RAM.
Disable
command issued
Posted-writes have been disabled by
the issuing of the Accelerator Disable
command. This occurred because of
an operating system device driver.
Restart the system. Run the Array Configuration
Utility (ACU) to reinitialize the array accelerator
board.
Drive (bay) X
firmware needs
upgrading
Firmware on this physical drive is
below the latest recommended
version.
Run the Options ROMPaq Utility to upgrade the
drive firmware to the latest revision.
Drive (bay) X has
insufficient
capacity for its
configuration
Drive has insufficient capacity to be
used in this logical drive
configuration.
Replace this drive with a larger capacity drive.
Drive (bay) X has
invalid M&P
stamp
Physical drive has invalid Monitor
and Performance data.
Run the BIOS Setup Utility to properly initialize
this drive.
Drive (bay) X has
loose cable
The array controller could not
communicate with this drive at
power up. This drive has not
previously failed.
Check all cable connections first. The cables
could be bad, loose, or disconnected. Power up
the system and attempt to reconnect
signal/power cable to the drive. If this does not
work, replace the cable. If that does not work,
the drive may need to be replaced.
Drive (bay) X is a
replacement
drive
This drive has been replaced. This
message displays if a drive is
replaced in a fault-tolerant logical
volume.
If the replacement was intentional, allow the
drive to rebuild.
continued