Chapter 4
Cabling Guidelines
Storage Device Installation Guidelines
This chapter provides an overview of the internal cabling of the
ProLiant ML350 chassis. It also includes information on how to cable SCSI,
IDE, and removable media devices in the system, as well as information about
all critical system cabling. If external cabling is required, please refer to the
documentation included with your external storage option device.
Consider the following guidelines when adding SCSI devices:
As a general rule, a maximum of seven devices may be added per
channel. Your server is equipped with two Wide-Ultra3 SCSI channels.
The configuration settings on each SCSI device should be set to the
SCSI ID of the bay (Bay 0 = SCSI ID 0) that it will occupy.
If only one SCSI hard drive is used, it should be installed in the
lowest-numbered bay (0).
Be sure to remove all terminating jumpers from third-party SCSI
devices.