Installation guide

3-38 Compaq ProLiant ML350 Setup and Installation Guide
For use with 1-GHz or greater Intel Pentium III processor-based server models only
Compaq Confidential Need to Know Required
Writer: Doug Warren Project: Compaq ProLiant ML350 Setup and Installation Guide Comments:
Part Number: 201345-001 File Name: d-ch3 Hardware Options Installation.doc Last Saved On: 7/24/00 9:23 AM
3. Slide the battery out of the holder. Lift the battery away from the
holder.
1
2
Figure 3-39. Removing the battery from the system board
4. Slide the replacement battery into the holder in the proper position.
IMPORTANT: Positive polarity (+) should be positioned facing out.
5. Reinstall the access panel.
6. Run the ROM Based Setup Utility (RBSU) to reconfigure your system.
Replacing the Battery on the Server Feature Board
WARNING: The system board contains a lithium battery. There is a risk of fire
and chemical burn if the battery is improperly handled. Do not disassemble,
crush, puncture, short external contacts, dispose of in water or fire, or expose it
to temperatures higher than 60°C (140°F).
CAUTION: Before removing the access panel, make sure that the server is
powered down, all cables are disconnected from the back of the server, and the
power cord is disconnected from the grounded (earthed) AC outlet.
CAUTION: Static electricity can damage electronic components of the server.
Before beginning these procedures, be sure you are discharged of static
electricity by briefly touching a grounded (earthed) metal object.