Installation guide

3-36 Compaq ProLiant ML350 Setup and Installation Guide
For use with 1-GHz or greater Intel Pentium III processor-based server models only
Compaq Confidential Need to Know Required
Writer: Doug Warren Project: Compaq ProLiant ML350 Setup and Installation Guide Comments:
Part Number: 201345-001 File Name: d-ch3 Hardware Options Installation.doc Last Saved On: 7/24/00 9:23 AM
Removing a Second Processor Power Module
(PPM)
1. Open the latches .
2. Remove the module from the socket on the system board.
1
Figure 3-37. Removing the Processor Power Module (PPM)
Replacing the Battery
The ProLiant ML350 has nonvolatile memory that requires a battery to retain
system information. There is a battery on the system board and a battery on the
Server Feature Board. These batteries are required to maintain certain system
data.
Replacing the Battery on the System Board
If your server no longer automatically displays the correct date and time, you
may need to replace the battery that provides power to the real-time clock.
When replacing a battery, use a CR2032 3-volt lithium coin cell battery.
After you have completed the battery installation, restart the system and run
RBSU (F9) to reconfigure your system.
WARNING: The system board contains a lithium battery. There is a risk of fire
and chemical burn if the battery is improperly handled. Do not disassemble,
crush, puncture, short external contacts, dispose of in water or fire, or expose it
to temperatures higher than 60°C (140°F).