Installing a Non-Hot-Plug Hard Drive into a
Non-Hot-Plug Drive Cage
To install a 3.5-inch non-hot-plug hard drive into a non-hot-plug drive cage:
CAUTION: Before removing the bezel, make sure that the server is powered
down, all cables are disconnected from the server, and the power cord is
disconnected from the grounded (earthed) AC outlet.
1. Follow the steps in “Removing the Access Panel” and “Removing the
Removable Media Device Blanks” earlier in this chapter.
2. Loosen the thumbscrews and remove the drive cage door .
1
2
Figure 3-9. Loosening the thumbscrews and removing the drive cage door
3. To configure the device, set the SCSI ID. You must manually set the
SCSI ID on each device to a unique value in the range of 0 to 6 for each
SCSI bus. Refer to the documentation provided with the drive for
instructions on setting the SCSI ID.
IMPORTANT: It is recommended that you set the SCSI ID equal to the bay number. See
Figure 3-7 for bay numbering.
4. Remove all terminating jumpers from third-party SCSI devices.
(Compaq SCSI non-hot-plug hard drive cables are terminated.)
5. Install two guide screws on each side of the drive. Be sure the rear
screws are secured in the holes farthest back on the drive and the guide
screws line up with the guide slots.