User guide
Table Of Contents
- HP ProLiant ML330 G6 Server User Guide
- Abstract
- Notice
- Contents
- Component identification
- Operations
- Setup
- Hardware options installation
- Introduction
- Processor option
- Memory options
- Redundant hot-plug power supply option
- Redundant fan assembly option
- SAS or SATA hard drive option
- Expansion hard drive cage option (hot-plug)
- Expansion hard drive cage option (non-hot-plug)
- Removable media devices
- Expansion board options
- PCI-X extender board option
- Storage controller option
- Battery-backed write cache battery pack option
- FBWC module and capacitor pack option
- SAS controller option
- Dedicated iLO 2 port module option
- HP Trusted Platform Module option
- Cabling
- Configuration and utilities
- Troubleshooting
- Battery replacement
- Regulatory compliance notices
- Regulatory compliance identification numbers
- Federal Communications Commission notice
- Declaration of conformity for products marked with the FCC logo, United States only
- Modifications
- Cables
- Canadian notice (Avis Canadien)
- European Union regulatory notice
- Disposal of waste equipment by users in private households in the European Union
- Japanese notice
- BSMI notice
- Korean notice
- Chinese notice
- Laser compliance
- Battery replacement notice
- Taiwan battery recycling notice
- Power cord statement for Japan
- Electrostatic discharge
- Specifications
- Technical support
- Acronyms and abbreviations
- Index

Specifications 122
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
• HP ProLiant 750 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
9.4 A at 100 VAC
4.7 A at 200 VAC
Rated input power
857 W at 100V AC input
852 W at 200V AC input
BTUs per hour
2924 at 100V AC input
2907 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Maximum peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
• HP ProLiant 460 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
10.0 A at 100 VAC
5.0 A at 200 VAC
Rated input power
626 W at 100V AC input
676 W at 200V AC input
BTUs per hour
2306 at 100V AC input
2306 at 200V AC input
Power supply output
Rated steady-state power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Maximum peak power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input