Specifications
Physical, Operating, and Performance Specifications 5-3
Power Supply
Table 5-2
Power Supply Specifications
General specifications
To 40°C and 1,525 m (to 104°F and 5,000 ft)
Full output rating
To 32°C and 3,050 m (to 90°F and 10,000 ft) (derate
linearly)
Minimum load 1.0 A on + 5V output
1.0 A on + 12V output
0.5 A on + 3.3V output
Ambient temperature range
Operating
10° to 40°C (50° to 104°F)
Storage
-40° to 65°C (-40° to 149°F)
Input specifications
Low Range/High Range
Nominal line voltage 100 to 120 VAC/200 to 240 VAC
Range input line 90 to 132 VAC/180 to 265 VAC
Frequency range 47 to 63 Hz/47 to 63 Hz
Power factor 0.95/0.95
Input power 500W @ 110V/750W @ 220V
Input current 8 A at 100 VAC/10 A at 200 VAC
Inrush current
<70 A at 132 VAC (cold start)/<70 A at 132 VAC (cold
start)
Holdup time 20 ms from zero crossing at 120 VAC/20 ms from zero
crossing at 120 VAC
Dielectric voltage withstand
Input to output 3000 VAC per minute/3000 VAC per minute
Input to ground 1500 VAC per minute/1500 VAC per minute
Input transient susceptibility
Common and differential mode
(superimposed on AC line)
2500V, 10 µs pulse
Differential mode 20% step change in AC input voltage