Specifications
Removal and replacement procedures 64
6.
Install the heatsink.
7. Install the air baffle ("Air baffle" on page 34).
8. Install the access panel ("Access panel" on page 33).
9. Slide the server into the rack.
10. Connect each power cord to the server.
11. Connect each power cord to the power source.
12. Power up the server.
DIMMs
IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
these two types causes the server to halt during BIOS initialization.
To identify the DIMMs installed in the server, see "DIMM slot locations (on page 90)."
To remove the component:
1. Power down the server (on page 27).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 28) or remove ("Remove the server from the rack" on
page 29) the server from the rack.
4. Remove the access panel ("Access panel" on page 33).