Specifications

Removal and replacement procedures 35
2U rack bezel
To remove the component:
Unlock the 2U rack bezel, press the latch on the 2U rack bezel, and then remove the 2U rack bezel.
To replace the component, reverse the removal procedure.
PCIe riser blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all PCI slots have either an expansion slot cover or an expansion board installed.
To remove the component:
1. Power down the server (on page 27).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 28) or remove ("Remove the server from the rack" on
page 29) the server from the rack.
4. Remove the access panel ("Access panel" on page 33).