Specifications
Removal and replacement procedures 61
PSU air baffle
To remove the component:
1. Power down the server (on page 30).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 31).
o Remove the server from the rack (on page 33).
4. Remove the access panel ("Access panel" on page 36).
5. If necessary, remove rear drive cables that are secured in the PSU air baffle latches.
6. Remove the PSU air baffle.
To replace the component, reverse the removal procedure.