After you add an I/O driver block to your Simulink model, you can select and
configure the I/O board installed in your computer. This procedure uses the
AD512 I/O board from Humusoft as an example:
1 Double-click an I/O driver block.
The
Block Parameters dialog box opens.
2 Click the Install new board button. From the list, point to a manufacturer,
and then click a board name. For example, point to Humusoft, and then click
AD512.
The I/O board dialog box opens. The name of this dialog box depends on
which I/O board you selected. The dialog box for the Humusoft AD512 board
is shown.
3 Select one of the following:
- For an ISA bus board, enter a base address. This value must match the
base address switches or jumpers set on the physical board. For example,
to enter a base address of
0x300 in the address box, type
300
You can also select the base address by selecting check boxes A9 through
A3.
- For a PCI bus board, enter the
PCI slot or select the Auto-detect check
box.