User`s guide

Diagnostics and Troubleshooting 6-23
Compaq Confidential – Need to Know Required
Writer: Everett Godaire Project: TL891 MiniLibrary System User's Guide Comments:
Part Number: ER-TL891-UA.A01 File Name: g-ch6 Diagnostics and Troubleshooting Last Saved On: 3/3/99 11:54 AM
Table 6-2
Fault Symptom Codes
continued
FSC Message Description
6043 Invalid Com Blk Type
A Slave inter-module process received
a packet from the Master inter-module
process, but the packet’s CommBlock
type was invalid.
6044 Invalid Com Blk Type
A Slave inter-module process received
a packet from the Status/Message
queue, but the packet’s CommBlock
type was invalid.
6045 Command Overlap
A Slave inter-module process received
a Command from the Master inter-
module process, but a previously
issued command is still being
executed.
6046 No Pkts To Send
A Slave inter-module process has
been requested to send a packet to
the Master inter-module process, but
the Slave inter-module process has no
packets to send.
6047 Invalid Direction
A Slave inter-module process has
received a direction control byte from
the Master inter-module process, but
the direction control byte is invalid.
6048
Master Pkt ID Bad
B001 Boot ROM CRC Error
B002 Boot RAM Test Failed
B004 Boot Comm Open Error
B005 Boot Novram Error
B006 Boot Unused Int
B007 Flash Init Error
B010 Boot UART 0 Error
continued