User`s guide

Diagnostics and Troubleshooting 6-7
Compaq Confidential – Need to Know Required
Writer: Everett Godaire Project: TL891 MiniLibrary System User's Guide Comments:
Part Number: ER-TL891-UA.A01 File Name: g-ch6 Diagnostics and Troubleshooting Last Saved On: 3/3/99 11:54 AM
Table 6-2
Fault Symptom Codes
continued
FSC Message Description
1001 SCSI Firmware Error
1002 SCSI FIFO Empty
While getting SCSI command bytes,
the SCSI chip reported an empty FIFO
before it was expected.
1003 SCSI FIFO Error
While getting SCSI command bytes,
the SCSI chip reported that the FIFO
was not empty when it should be
empty.
1004 SCSI Gross Error
Gross error status was returned by the
SCSI chip. This usually means that the
SCSI chip is in an illegal state.
1005 Illegal SCSI Cnt Cmd
The SCSI chip rejected a command
from the firmware.
1006 SCSI Message Error Not reported
1007 SCSI Invalid Element
Firmware error
1008 SCSI No Pending Int
An interrupt was returned from the
SCSI chip when one was not expected.
1009 SCSI Invalid Int
An invalid interrupt was returned from
the SCSI chip.
1020 No Active Command
Status was returned from the control
process when no command was
active.
1021 SCSI Invalid Request
An invalid request was received from
the control process (firmware error).
1022 SCSI Invalid Semaphore
Firmware Error
1023 SCSI Invalid State Firmware Error
1024 SCSI Invalid Ctl Msg
A message sent from the control
process was not valid.
continued