Table 6-3
Diagnostic Error Messages
continued
Message Description Probable Cause Action
DIAG-MEMORY
Err#0110
[ramTest]
Data read from the RAM location
did not match previously written
data into the same location.
CPU RAM failure Replace motherboard
assembly or DRAM
module
DIAG-PORTABSENT
Err#2670, 3070,
3870
[portLoopbackTest,
crossPortTest,
spinSilk]
A port is not present. ASIC or
motherboard
failure
Replace motherboard
assembly
DIAG-PORTDIED
Err#265F, 305F,
385F
[portLoopbackTest,
crossPortTest,
spinSilk]
A port was in loopback mode and
then went inactive.
ASIC, GBIC
module, or fiber
cable failure
Replace motherboard
assembly, GBIC
module, or fiber cable
DIAG-PORTSTOPPED
Err#3874
[spinSilk]
A port is no longer transmitting:
the Number Of Frames
Transmitted counter is stuck at N
frames.
ASIC, GBIC
module, or fiber
cable failure
Replace motherboard
assembly, GBIC
module, or fiber cable
DIAG-PORTWRONG
Err#3078
[crossPortTest]
A frame was erroneously
received by port M instead of the
intended port N.
ASIC failure Replace motherboard
assembly
DIAG-POST_SKIPPED
Err# 0004
[switch initialization]
POST is skipped. A message
recommends that POST be
executed.
Informational
Only
None required
DIAG-REGERR
Err#0B15, 0415
[portRegTest,
sramRetentionTest]
Data read from an ASIC register
or an ASIC SRAM did not match
data previously written into the
same location.
ASIC failure Replace motherboard
assembly
continued