Specifications
6-10
   Compaq StorageWorks SAN Switch 16 Installation and Hardware Guide
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 16 Installation and Hardware Guide Comments: 
Part Number: EK-BCP28-IA / 161356-001 File Name: G-CH6 ERROR MESSAGES.DOC Last Saved On: 9/30/99 11:32 AM
Table 6-3
Diagnostic Error Messages 
continued
Message Description Probable Cause Action
DIAG-CMBISRTO
Err#1020
[centralMemoryTest]
An ASIC’s Central Memory
SRAMs did not complete the
BISR within the timeout period.
ASIC failure Replace motherboard
assembly
DIAG-CMERRPTN
Err#102B
[centralMemoryTest]
An error was detected at the
wrong port.
ASIC failure Replace motherboard
assembly
DIAG-CMERRTYPE
Err#102A
[centralMemoryTest]
A port received the wrong CMEM
error type.
ASIC failure Replace motherboard
assembly
DIAG-CMICKSUM
Err#2036
[cmiTest]
A CMI message received a failed
bad checksum test.
ASIC or
motherboard
failure
Replace motherboard
assembly
DIAG-CMIDATA
Err#2035
[cmiTest]
CMI data received did not match
the data transmitted.
ASIC or
motherboard
failure
Replace motherboard
assembly
DIAG-CMIINVCAP
Err#2034
[cmiTest]
An unintended ASIC erroneously
received a CMI capture flag.
ASIC or
motherboard
failure
Replace motherboard
assembly
DIAG-CMINOCAP
Err#2033
[cmiTest]
A CMI intended receiver ASIC
failed to receive a CMI capture
flag.
ASIC or
motherboard
failure
Replace motherboard
assembly
DIAG-CMISA1
Err#2032
[cmiTest]
An attempt to send a CMI
message from ASIC to ASIC
failed.
ASIC failure Replace motherboard
assembly
DIAG-CMNOBUF
Err#1029
[centralMemoryTest]
A port could not receive a buffer. ASIC failure Replace motherboard
assembly
continued