Specifications
Front Panel Switch Management  
4-17
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 16 Installation and Hardware Guide Comments: 
Part Number: EK-BCP28-IA / 161356-001 File Name: E-CH4 FRONT PANEL SWITCH MANAGEMENT.DOC Last Saved On: 9/30/99 11:27 AM
Port Throughput
To view the port throughput on the switch, press <Enter> while Port Throughput
displays on the front panel. The throughput number represents the number of
bytes received plus the number of bytes transmitted per second and is
displayed as bytes per second (B/s), kilobytes per second (KB/s), or megabytes
per second (MB/s). You can select different ports using <Up> and <Down> to
monitor a single port or aggregate port performance.
Temperature
To view the temperature of the switch from five sensors on the motherboard,
press <Enter> while 
Temperature displays on the front panel. Using <Up> or
<Down>, you can toggle between Centigrade and Fahrenheit temperature
values. The temperature readings display on the front panel at a rate of one
reading per second. Readings obtained during a Telnet session represent a
single reading made at command execution.
Error Log
To view the error log, press <Enter> while Error Log displays on the front panel.
The error log stores the last 64 error types sensed by the switch. The front
panel display shows:
■
Error number (01-64)
■
Date and time of the last occurrence
■
Total number of occurrences of each error type
■
Error type
■
Error level for each error type
0—Panic (when this level is reached, the switch automatically
reboots and the display no longer shows the error)
1—Critical
2—Error
3—Warning
4—Info
5—Debug