Specifications

1-4 Compaq ProLiant ML350 Generation 2 Tower-to-Rack Conversion Guide
Compaq Confidential Need to Know Required
Writer: Jennifer Hayward Project: Compaq ProLiant ML350 Generation 2 Tower-to-Rack Conversion Guide Comments:
Part Number: 236991-001 File Name: b-ch1 Preparing the Server.doc Last Saved On: 7/10/01 1:05 PM
Removing Tower-Specific Chassis Components
Before beginning these procedures, make sure that you understand the
following precautions.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the
hard drives and internal system components to cool before touching them.
CAUTION: Electrostatic discharge (ESD) can damage electronic components.
Refer to Appendix A for ESD information before you remove or install server
parts.
When you convert a ProLiant ML350 Generation 2 tower model server to a
rack-mountable model, you must first remove the following components:
Bezel door
Feet
Locking bracket
Tower configuration panel
After removing the components, it is necessary to set the system board switch
to a rack configuration. See “Setting the System Configuration Switch” later in
this chapter for detailed instructions.