Technical information

15
1.44MB 3.5” diskette drive
IDE CD-ROM
PSU
Memory Daughter Board
SVGA Graphics Std
PCI Ethernet Adapter Std
Narrow SCSI
Ultra2/LVD SCSI
PCI Slot 3
PCI Slot 1
PCI Slot 2
PCI Slot 4
Shared PCI/ISA Slot
2345
PSU
PSU
8 hot-
swap disk
bays
All disks
are front
acces s ibl e
7
hot-
swap
fans
PCI Slot 5
617
12345678
8
4
CPUs
Uninterrupted Power Supply products What to order
1.4kVA UPS Base Package (220-240V)
UPS-to-server power cables (pack of two)
SV537005
SV537040
2.2kVA UPS Base Package (220-240V)
Mains Cable (UK) for powering 2.2kVA UPS
Mains Cable (European) for powering 2.2kVA UPS
SV537016
SV537039
SV537042
PowerChute software for UnixWare 7 SV537043
teamserver
L8
00i Options
What to order
Additional PSU for
L800i
SV578111
Hot-Swap Replacement Fan SV578113
Server Manager Assist for
L800i
SV000143
External SCSI connection for ext. tape SV521037
Server is supplied with 2 PSUs.
For hot-swap redundancy, an additional PSU is required.
Each PSU requires a separately orderable mains cable.
Hot-swap fans located in 3 places in system cabinet.
Internal Backup Devices
(Maximum of 2 devices)
What to
order
4-8GB SLR5 QIC tape drive SV546035
4-8GB DDS-2 4mm DAT tape drive SV520009
12-24GB DDS-3 4mm DAT tape drive SV546012
OR one from
20-40GB DLT4000 tape drive SV546034
External Backup Devices
20-40GB DLT4000 tape drive SV546006
35-70GB DLT7000 tape drive* SV546037
60-120GB DDS-3 4mm DAT Stacker SV546038
280-560GB DLT7000 Autoloader# (NT only) SV546045
* Includes SCSI cable for connection to Adaptec 2940UW
# Includes SCSI cable for connection to Adaptec 2944UW
Disk Capacity Required What to
order
4 GB 1” 7200rpm SCA Ultra2/LVD SCSI SV565054
9 GB 1” 7200rpm SCA Ultra2/LVD SCSI SV565060
18 GB 1” 7200rpm SCA Ultra2/LVD SCSI SV565061
9 GB 1” 10,000rpm SCA Ultra2/LVD SCSI SV565063
18 GB 1” 10,000rpm SCA Ultra2/LVD SCSI SV565064
36 GB 1.6” 10,000rpm SCA Ultra2/LVD SCSI SV565065
Maximum of 252GB disk in system cabinet from
6 x 36GB 1.6” disks and 2 x 18GB 1” disks (10k rpm).
For RAID systems, order PCI RAID Card SV521032 or
SV521036. Do not mix 10,000 and 7200 rpm disks on
the same RAID controller.
NB. For RAID 5 configurations it is recommended that
the disks are all of the same capacity
e.g. All 4GB, 9GB, 18GB or 36GB disks.
CPU note: 1½ voltage regulators required per
processor, 6 voltage regulators are available.
SVGA note: Cirrus Logic CL-GD5480 with 2MB
VRAM, is not upgradeable.
teamserver
L800i base configurations
What to
order
teamserver
L870i
, 500MHz/512KB Pentium III
Xeon CPU, no HDD, no RAM
SV656063
teamserver
L870i
, 500MHz/512KB Pentium III
Xeon CPU, no HDD, 128MB RAM
SV656066
(SV656065)
teamserver
L880i
, 500MHz/1MB Pentium III Xeon
CPU, no HDD, no RAM
SV656064
teamserver
L880i
, 500MHz/1MB Pentium III Xeon
CPU, no HDD, 128MB RAM
SV656067
(SV656068)
teamserver
L870ie
, 550MHz/512KB Pentium III
Xeon CPU, no HDD, no RAM
SV656085
teamserver
L880ie
, 550MHz/1MB Pentium III Xeon
CPU, no HDD, no RAM
SV656086
teamserver
L890ie
, 550MHz/2MB Pentium III Xeon
CPU, no HDD, no RAM
SV656091
System pre-installed with Intel PRO/100+ Management Adapter
UK server which includes UK keyboard, mouse and two power cables.
There are no UK versions of the L8x0
i
/Z models because these “zero config”
servers are intended to be minimal configu.rations
Processor upgrades What to
order
team
server
L800
i
500MHz/512KB Pentium III Xeon
SV656069
team
server
L800
i
500MHz/1MB Pentium III Xeon
SV656070
team
server
L800
i
550MHz/512KB Pentium III Xeon
SV656089
team
server
L800
i
550MHz/1MB Pentium III Xeon
SV656090
team
server
L800
i
550MHz/2MB Pentium III Xeon
SV656093
PCI I/O Adapters
(Intel PRO/100+ Management Adapter as standard)
What to
order
Intel EtherExpress PRO/10+ PCI adapter (Ethernet)* SV520048
Intel PRO/100+ Server Adapter (Ethernet)* SV520056
Intel PRO/1000 Gigabit Ethernet Server Adapter* SV520059
Adaptec AHA2940UW SE SC SCSI Adapter
External SCSI cable 2m (Adaptec to ext tape dev)
SV521002
SV561009
Adaptec AHA2944UW Differential SCSI Adapter SV521016
Mylex eXtremeRAID 1100 Ultra2 SCSI RAID adapter
(32MB, with battery)
SV521036
SXPCI 32-bit Async Adapter
4-port Terminal Adapter for SXPCI Async Adapter
8-port Terminal Adapter for SXPCI Async Adapter
SV521027
SV520015
SV520016
RIO 128-bit Async Adapter
16-port RTA with DB25 connector
16-port RTA with RJ45 connector
SV521028
SV521030
SV521031
Olicom Token-Ring 16/4 Adapter (OC3140) SV520058
P92 dual-port WAN Adapter*
V.24 cable for P92 WAN Adapter
X.21 cable for P92 WAN Adapter
SV630002
SV630003
SV630004
FDDI Adapter: Dual Attach Station (DAS) (SK5544)* SV631002
* Refer to PD for operating system restrictions
ECC EDO Memory What to
order
128MB RAM (4 * 32MB registered DIMM) SV656007
256MB RAM (4 * 64MB registered DIMM) SV656008
512MB RAM (4 * 128MB registered DIMM) SV656009
1024MB RAM (4 * 256MB registered DIMM) SV656010
Four way interleaved memory requires memory to be
installed in banks of 4 DIMMs, pair on left & pair on right of
memory daughter board.
i.e. Those servers supplied with 128MB or 256MB RAM, are
comprised of 4 * 32MB or 4 * 64MB DIMMs respectively
.
Mains Lead Sets What to
order
European 57495001
UK, Asia 57495002
United States 57495004
Australia, Fiji, New Zealand order locally
team
server
L870
i,
L880
i,
L870
ie,
L880
ie
and L890
ie