Technical data

OSM changes for H06.26/J06.15
OSM T0682 H02 ADD added support for:
Added the following new section: “Configuring Non-Default Users” (page 71).
Updated note in following sections regarding the configuration of non-default users: “OSM
Low-Level Link” (page 63), “NonStop Maintenance LAN DHCP DNS Configuration Wizard”
(page 70), and “Down System CLIM Firmware Update Tool” (page 71).
Updated “Configuring Secure Sockets Layer (SSL) Support” (page 22) as SSL is now enabled
by default for T0682 H02 ADD (or later).
Updated “Functional Differences” (page 68) to include the time-stamped enhancement.
Updated “OSM Client-Based Applications” (page 38) to include new Apache OpenOffice
tool.
Updated the requirements in “System Console Requirements” (page 11).
Updated some of the logging steps in “Logging On” (page 60).
OSM Changes for H06.25/J06.14
OSM T0682 H02 ACZ added support for:
Support for HP Integrity NonStop NS2100 servers.
A new guided procedure to make the replacement of CLIMs and CLIM Hard Drives more
automated, see Table 2 (page 62).
Support for “Suppressing BladeCluster Alarms (page 52) a new Place Local Node in Service
action on the BladeCluster object can be performed to prevent all other directly-connected
nodes from remotely notifying (dialing out) an alarm as soon as SNETMON is stopped or the
node is halted.
Support for “Suppressing Specific Alarms (page 17) based on a specific problem and resource
name, by adding an OSMCONF parameter.
Support for “Specifying Alternate Collector for OSM Event Viewer” (page 16), by adding an
OSMCONF parameter.
Support for “Binding to an IP Address and Stack for OSM when Sending Indications (page 17),
by adding an OSMCONF parameter.
Updated “Configuring Additional TCP/IP Processes for OSM Connectivity” (page 18).
Updated “Example: How To Generate a Private SSL Certificate Using OpenSSL” (page 26)
Updated the Subject Alternate Name (SAN) description and added an example in
“Requirements for Generating and Activating a Private SSL Certificate” (page 23)
Updated “HP Systems Insight Manager (SIM)” (page 39) and “HP Insight Control Power
Management” (page 39).
OSM Changes for H06.24/J06.13
OSM T0682 H02 ACV added support for:
Support for using IPv6 on the operations LAN, including an OSMCONF setting for “Enabling
IPv6 Support” (page 32).
Support for Core Licensing on HP Integrity NonStop BladeSystems NB54000c and
NB54000c-CG . For information on related attributes and actions (including a new guided
procedure), see the OSM Service Connection online help.
Support for NonStop system consoles running Microsoft Windows Server 2008.
Recent H- and J-Series OSM Change Highlights 7