Technical data
OSM changes for H06.26/J06.15
OSM T0682 H02 ADD added support for:
• Added the following new section: “Configuring Non-Default Users” (page 71).
• Updated note in following sections regarding the configuration of non-default users: “OSM
Low-Level Link” (page 63), “NonStop Maintenance LAN DHCP DNS Configuration Wizard”
(page 70), and “Down System CLIM Firmware Update Tool” (page 71).
• Updated “Configuring Secure Sockets Layer (SSL) Support” (page 22) as SSL is now enabled
by default for T0682 H02 ADD (or later).
• Updated “Functional Differences” (page 68) to include the time-stamped enhancement.
• Updated “OSM Client-Based Applications” (page 38) to include new Apache OpenOffice
tool.
• Updated the requirements in “System Console Requirements” (page 11).
• Updated some of the logging steps in “Logging On” (page 60).
OSM Changes for H06.25/J06.14
OSM T0682 H02 ACZ added support for:
• Support for HP Integrity NonStop NS2100 servers.
• A new guided procedure to make the replacement of CLIMs and CLIM Hard Drives more
automated, see Table 2 (page 62).
• Support for “Suppressing BladeCluster Alarms” (page 52) – a new Place Local Node in Service
action on the BladeCluster object can be performed to prevent all other directly-connected
nodes from remotely notifying (dialing out) an alarm as soon as SNETMON is stopped or the
node is halted.
• Support for “Suppressing Specific Alarms” (page 17) based on a specific problem and resource
name, by adding an OSMCONF parameter.
• Support for “Specifying Alternate Collector for OSM Event Viewer” (page 16), by adding an
OSMCONF parameter.
• Support for “Binding to an IP Address and Stack for OSM when Sending Indications” (page 17),
by adding an OSMCONF parameter.
• Updated “Configuring Additional TCP/IP Processes for OSM Connectivity” (page 18).
• Updated “Example: How To Generate a Private SSL Certificate Using OpenSSL” (page 26)
• Updated the Subject Alternate Name (SAN) description and added an example in
“Requirements for Generating and Activating a Private SSL Certificate” (page 23)
• Updated “HP Systems Insight Manager (SIM)” (page 39) and “HP Insight Control Power
Management” (page 39).
OSM Changes for H06.24/J06.13
OSM T0682 H02 ACV added support for:
• Support for using IPv6 on the operations LAN, including an OSMCONF setting for “Enabling
IPv6 Support” (page 32).
• Support for Core Licensing on HP Integrity NonStop BladeSystems NB54000c and
NB54000c-CG . For information on related attributes and actions (including a new guided
procedure), see the OSM Service Connection online help.
• Support for NonStop system consoles running Microsoft Windows Server 2008.
Recent H- and J-Series OSM Change Highlights 7