Technical data

Table 2 OSM Guided Procedures and Service Actions (continued)
How to AccessFunction
Documented procedure launched by Replace action on the
enclosure or component to be replaced.
Replace (FCDM) Disk Drive Enclosure or component
Documented procedure launched by Replace action on the 4PSE
object (Integrity NonStop NS14000 or NS1000 servers with
IOAM enclosure only).
Replace 4-Port ServerNet Extender (4PSE)
OSM guided procedures, launched by actions of the same names
on the System object in the OSM Service Connection, help you
Check Storage Dependence on ServerNet Fabric
Bring Up and Balance Storage Paths
prepare for and recover from activities that disrupt ServerNet
traffic on one fabric.
For Integrity NonStop NS14000 or NS1000 servers with VIO
enclosures only, documented replacement procedures are
Replacing a VIO Logic Board and other components
launched by Replace action on the VIO Module, VIO Logic Board,
VIO G4SA, Optical Extender PIC, VIO Power Supply, and VIO
Fan objects.
NonStop S-Series Hardware (applicable to NS-series
as a legacy attachment)
OSM guided procedures launched by Replace action on the CRU
to be replaced.
Replace IOMF or SNDA
Interactive Replace action on the Power Supply to be replaced.Replace Power Supply
ServerNet Cluster
OSM guided procedure launched by Add Node to ServerNet
Cluster action on the System object. This is used for adding the
system as a member of either a ServerNet Cluster or BladeCluster.
Adding a node to a ServerNet Cluster
OSM Guided procedure launched by Replace action on both
6770 and 6780 switch modules.
Replace Switch Component
Interactive Update Topology action that guides you in updating
the network topology of a ServerNet cluster.
Update Topology
Interactive External Loopback Test action for ServerNet PICs on
IOMF2 CRU.
Troubleshoot ServerNet Fabric
Unique to NonStop BladeSystems
Documented procedure launched by Replace action on the
processor blade to be replaced.
Replace Processor Blade
Documented procedure launched by Replace action on the
ServerNet switch to be replaced.
Replace ServerNet Switch
This action, located on the System object, launches an OSM
guided procedure that copies the core license file from $SYSTEM
to the specified alternate system disk.
Install Core License File
For more information about performing OSM actions, including interactive actions, see the OSM
Service Connection User’s Guide (also available as online help within the OSM Service Connection).
For more information about a specific guided procedure, see the online help within that guided
procedure. The guided procedure interface is launched when you click Perform Action for the
action associated with each guided procedure.
OSM Low-Level Link
The OSM Low-Level Link (LLL), one of the OSM Client-Based Applications, is primarily designed
for down-system support. It enables you to communicate with a server even when the NonStop
Kernel operating system is not running. Additionally, some actions performed on a running server,
OSM Low-Level Link 63