Specifications

7–138
CLI Commands
This example shows the full information for a controller:
SHOW THIS_CONTROLLER FULL
Controller:
HSG80 (C) DEC CX00001905 Software R024F-0, Hardware 0000
NODE_ID = XXXX-XXXX-XXXX-XXXX
ALLOCATION_CLASS = 767
SCSI_VERSION = SCSI-2
Configured for dual-redundancy with ZG83301871
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is lun 0 (IDENTIFIER = 8888)
Host PORT_1:
Reported PORT_ID = XXXX-XXXX-XXXX-XXXX
PORT_1_PROFILE = PLDA
PORT_1_TOPOLOGY = FABRIC (FABRIC UP)
Address = 200113
NOREMOTE_COPY
Host PORT_2:
Reported PORT_ID = XXXX-XXXX-XXXX-XXXX
PORT_2_PROFILE = PLDA
PORT_2_TOPOLOGY = FABRIC (standby)
Address = 200413
Cache
256 megabyte write cache, version 0012
Cache is GOOD
Unflushed data in cache