Specifications

7–102
CLI Commands
Storagesets cannot be made transportable. Specify NOTRANSPORTABLE for all disks
used in RAIDsets, stripesets, mirrorsets, and sparesets. Transportable disks do not
contain any metadata or restricted areas on the disk. Therefore, transportable disks
forfeit the advantage metadata provides. Transportable disks can be moved to a non-
StorageWorks environment with their data intact.
If you specify the NOTRANSPORTABLE switch and there is no metadata on the
unit, the unit must be initialized. If you specify TRANSPORTABLE for a disk that
was originally initialized as a NOTRANSPORTABLE, you should initialize the disk.
NOTE: Compaq recommends you avoid specifying TRANSPORTABLE unless
transportability of the device or media is imperative and there is no other way to
accomplish moving the data.
Examples
This example shows how to set the data transfer rate of DISK20000 to 5MHz:
SET DISK20000 TRANSFER_RATE_REQUESTED=5MHZ
This example shows how to set DISK10300 to transportable:
SET DISK10300 TRANSPORTABLE
See also
ADD DISK
SHOW DISKS