Specifications

7–99
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
It also specifies how the command console LUN is handled. The command console
LUN (CCL) presents to the GUI a virtual LUN through which it communicates with
the controller.
SCSI-2 specifies that the CCL is not fixed at a particular location, but floats
depending on the configuration.
SCSI-3 specifies that the CCL is fixed at LUN 0. The SCSI device-type returned to
the host is array controller.
Changes to this switch take place at the next controller restart.
TERMINAL_PARITY=ODD
TERMINAL_PARITY=EVEN
NOTERMINAL_PARITY (Default)
Specifies the parity with which data is transmitted and received. When changed, the
new setting for this switch takes effect immediately.
TERMINAL_SPEED=baud_rate
TERMINAL_SPEED=9600 (Default)
Sets the terminal transmission and reception speed (baud rate) to 4800, 9600
(default), or 19200 baud. When changed, the new value entered for this switch takes
effect immediately.
TIME=ddmmmyyyy:hh:mm:ss
Sets the date and time. The time is set on both controllers in a dual-redundant
configuration.When changed, the new value entered for this switch takes effect
immediately.