Specifications
7–95
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
CAUTION: Setting CACHE_UPS without having a UPS or similar backup
system in place may result in data loss if power is interrupted.
Specify NOCACHE_UPS to instruct the controller to perform regular cache battery
checks and evaluate the condition of the cache batteries.
Setting the CACHE_UPS switch for either controller sets the CACHE_UPS switch
for both controllers.
COMMAND_CONSOLE_LUN
NOCOMMAND_CONSOLE_LUN (Default)
Enables or disables the virtual LUN used with the StorageWorks Command Console.
When changed, the new setting for this switch takes effect immediately.
NOTE: This switch enables (COMMAND_CONSOLE_LUN) and disables
(NOCOMMAND_CONSOLE_LUN) the CCL in SCSI-2 mode only. This switch has no
effect in SCSI-3 mode.
Select COMMAND_CONSOLE_LUN to enable the virtual LUN. Select
NOCOMMAND_CONSOLE_LUN to disable the virtual LUN.
IDENTIFIER= n
NOIDENTIFIER
The IDENTIFIER switch is used with the SCSI_VERSION switch when the SCSI
version is set to SCSI-3 mode. The IDENTIFIER switch creates a CCL identifier that
makes the controller and the CCL visible to the host. This number can be a value
between 1–9999.
From the controller perspective, the IDENTIFIER switch provides an alternative way
(other than worldwide name) for OpenVMS operating systems to identify the CCL.