Specifications
6–25
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Moving Storagesets
You can move a storageset from one subsystem to another without destroying its data
as shown in Figure 6–1. You also can follow the steps in this section to move a
storageset to a new location within the same subsystem.
CAUTION: Move only normal storagesets. Do not move storagesets that
are reconstructing or reduced, or data corruption will result.
You can use the procedure in this section to migrate wide devices from an HSZ70
controller in a BA370 rack-mountable enclosure to an HSG80 environment. However,
if you have an HSZ40 or HSZ50 subsystem, you cannot migrate to an HSG80 in a
BA370 rack-mountable enclosure. Refer to the StorageWorks Array Controller
HSG80 Array Controller Operating Software ACS Version 8.3 Release Notes for
drives that can be supported.
Figure 6–1 Moving a Storageset from one Subsystem to Another
CAUTION: Never initialize any container or this procedure will not pro-
tect data.
CXO5595A