Specifications

6–15
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
ADD UNIT D1 Raid1 PARTITION=1
ADD UNIT D2 Raid1 PARTITION=2
ADD UNIT D3 Raid1 PARTITION=3
ADD UNIT D4 Raid1 PARTITION=4
SHOW Raid1
.
.
.
Chapter 7, “CLI Commands,” contains more information on partitioning a storageset
or disk drive.
Adding a Disk Drive to the Spareset
The spareset is a collection of hot spares that are available to the controller should it
need to replace a failed member of a RAIDset or mirrorset.
Use the following steps to add a disk drive to the spareset:
NOTE: This procedure assumes that the disks that you are adding to the spareset
have already been added to the controller’s list of eligible devices.
1. Add the disk drive to the controllers spareset list. Use the following command:
ADD SPARESET disk
nnnnn
Repeat this step for each disk drive you want to add to the spareset:
Partition number Size Starting Block Used by
1 1915 (0.98 MB) 0 D1
2 1915 (0.98 MB) 1920 D2
3 1915 (0.98 MB) 3840 D3
4 2371 (1.21 MB) 5760 D4
.
.
.