Specifications
6–8
Configuring Storagesets
1–9999. Usually, this number is the same as the unit number set in step 3.
SET
unit-number
identifier
=
nnnn
4. Verify the mirrorset configuration and switches. Use the following command:
SHOW
mirrorset-name
5. Verify the unit configuration and switches. Use the following command:
SHOW
unit-number
Example
The following example shows the commands you would use to create Mirr1, a two-
member stripeset:
ADD MIRRORSET Mirr1 disk10000 disk20000
INITIALIZE Mirr1
ADD UNIT D110 Mirr1
SHOW Mirr1
SHOW D110
Refer to Chapter 7, “CLI Commands,” for more information on the
ADD_MIRRORSET, INITIALIZE, ADD_UNIT, and SHOW commands for creating
a mirrrorset.
Configuring a RAIDset
To configure a RAIDset:
1. Create the RAIDset by adding its name to the controller’s list of storagesets and
specifying the disk drives it contains. Optionally, you can append RAIDset
switch values. If you do not specify switch values, the default values are applied.
Use the following command to create a RAIDset:
ADD RAIDSET
RAIDset-name
DISK
nnnnn
DISK
nnnnn
DISK
nnnnn switch