Specifications

6–7
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
The following example shows the commands you would use to create Stripe1, a
three-member stripeset:
ADD STRIPESET STRIPE1 disk10000 disk20000 disk30000
INITIALIZE STRIPE1 CHUNKSIZE=128
ADD UNIT D100 STRIPE1 MAXIMUM_CACHED_TRANSFER=16
SHOW STRIPE1
SHOW D100
See Chapter 7, “CLI Commands,” for more information on stripeset switches and
values.
Configuring a Mirrorset
See Chapter 4, “Planning Storagesets,” for information about creating a profile and
understanding the switches you can set for this kind of storage unit.
To configure a mirrorset:
1. Create the mirrorset by adding its name to the controller’s list of storagesets and
specifying the disk drives it contains. Optionally, you can append Mirrorset
switch values. If you do not specify switch values, the default values are applied.
Use the following command to create a mirrorset:
ADD MIRRORSET
mirrorset-name
DISK
nnnnn
DISK
nnnnn switch
2. Initialize the mirrorset. If you want to set any Initialize switches, you must do so
in this step. Use the following command:
INITIALIZE
mirrorset-name
switch
3. Present the mirrorset to the host by giving it a unit number the host can recognize.
Optionally, you can append Unit switch values. If you do not specify switch
values, the default values are applied. Use the following command:
ADD UNIT
unit-number
mirrorset-name switch
a. For OpenVMS hosts, set the unit number to a decimal value, ranging from