Specifications
5–29
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Optional Steps
Following are some of the more common steps that can be performed anytime during
configuring.
Changing the CLI Prompt
Enter a 1- to 16-character string as the new prompt. For example, you could use the
prompt to indicate the controller’s name, such as “HSG1.”
Type the following command:
SET THIS_CONTROLLER PROMPT = “new prompt”
If you are configuring dual-redundant controllers, you can also change the CLI
prompt on it. Use the following command:
SET OTHER_CONTROLLER PROMPT = “new prompt”
See “SET controller,” page 7–91.
Setting the PVA Module ID Switch
The Power, Verification, and Addressing (PVA) module provides unique addresses to
extended subsystems. Each BA370 rack-mountable enclosure in an extended
subsystem must have its own PVA ID. Use PVA ID 0 for the enclosure that contains
the array controllers. Use PVA IDs 2 and 3 for the additional enclosures. Figure 5–8
illustrates the PVA settings in an extended subsystem.
See the documentation that accompanied your enclosure for more details about the
PVA and its settings.