Specifications

5–7
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
7. Set the time on the controller, which provides a baseline for replacing the
external battery, using the following command:
SET THIS_CONTROLLER TIME=DD-MMM-YYYY:HH:MM:SS
NOTE: All values are numbers, except for MMM, which uses the first three
letters of the month. When setting hours, minutes, and seconds—HH, MM,
and SS—you must use 24-hour time.
8. Set up the battery discharge timer:
a. Start Frutil using the following command:
RUN FRUTIL
Frutil displays the following:
Do you intend to replace this controller’s cache battery? Y/N
b. Enter Y(es).
Frutil displays a three-step procedure and prompts you to press return.
c. Press return.
9. Enter any other optional CLI commands for your configuration.
See “Optional Steps,” page 5–29 and Chapter 7, “CLI Commands.”
10. Display details about the controller you configured. Use the following command:
SHOW THIS_CONTROLLER FULL
See “SHOW,” page 7–133.
IMPORTANT: If you are using a PC or terminal with the maintenance port cable
during configuring and have not yet cabled the configuration, you must connect
the optical host bus cables in the desired configuration as shown in the next
section.