5–5
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Tips
As you configure the controller, keep these points in mind:
■ Cabling—You can either configure the controller with a maintenance port cable
and no optical host bus cables connected to the host, or you can configure with
the optical host bus cables connected:
❏ SWCC—You can configure the controller using the SWCC graphical user
interface. See the Command Console for HSG80 Solutions Getting Started Guide
for more details.
❏ CLI Commands—You can configure the controller with CLI commands
using a terminal program.
NOTE: Eventually, you must connect the optical host bus cables between the
controllers and the host. You can connect the optical host bus cables after
configuring the controllers using a maintenance port cable.
■ EMU Alarm Control Switch—If the EMU alarm goes off, simply press it to stop
it. Check the error message to verify the type of error condition.
■ CLI Commands—You can use the following CLI commands frequently while
configuring the controller:
❏ CLEAR_ERRORS CLI—Clears all error messages so you can type without the
messages being repeated. Make sure you read each error message before clearing
it.
❏ SHOW THIS_CONTROLLER FULL and SHOW OTHER_CONTROLLER FULL—Lists
the full information about the controller.