Specifications

3–12 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
During the installation, the source disk drive is not available for other subsystem
operations.
Some devices might not reflect the new firmware version number when viewed from
the other controller” in a dual-redundant controller configuration. If this occurs, enter
the following CLI command: CLEAR_ERRORS device-name UNKNOWN.
Do not issue any CLI commands that access or inspect devices that are being
formatted.
Use the following steps to upgrade firmware with HSUTIL:
1. Connect a PC or terminal to the controller maintenance port that accesses the device
being upgraded.
2. Configure a single-disk unit.
NOTE: In the next steps, the firmware image is copied to this unit and HSUTIL is used to
distribute it to the devices being upgraded. This unit must be a newly initialized disk with no
label or file structure to ensure that the firmware image resides in contiguous blocks starting
from LBN 0 or another known LBN. Additionally, write-back caching must be disabled (see
HSG80 Array Controller ACS Version 8.5 Configuration Guide
.
3. Copy the firmware image to the single-disk unit configured in step 2. The firmware
image must begin at a known LBN—usually 0—and must be contiguous.
See the documentation that accompanied the host operating system for instructions on
copying firmware images to a disk drive.
CAUTION: The host load must be quiesced before running HSUTIL; otherwise,
damage to the storage device can occur.
4. Start HSUTIL with the following command:
RUN HSUTIL
The following menu appears:
HSUTIL Main Menu:
0. Exit
1. Disk Format
2. Disk Device Code Load
3. Tape Device Code Load
4. Disaster Tolerance Backend Controller Code Load
Enter function number: (0:4) [0]?
5. Enter option 2.