Specifications
Upgrading the Subsystem 3–7
4. Start CLCP with the following command:
RUN CLCP
The following menu appears:
Select an option from the following list:
Code Load & Patch local program Main Menu
0: Exit
1: Enter Code LOAD local program
2: Enter Code PATCH local program
3: Enter EMU Code LOAD utility
Enter option number (0..3) [0] ?
5. Enter option 2. The following menu appears:
You have selected the Code Patch local program. This program is used to
manage software code patches. Select an option from the following list:
Type ^Y or ^C (then RETURN) at any time to abort Code Patch.
Code Patch Main Menu
0: Exit
1: Enter a Patch
2: Delete Patches
3: List Patches
Enter option number (0..3) [0] ?
6. Enter option 1. The following display appears:
This is the Enter a Code Patch option. The program prompts you for the
patch information, one line at time. Be careful to enter the information
exactly as it appears on the patch release. Patches may be installed for
any version of software; however, patches entered for software versions
other than XXXXX are not applied until the matching version of software
is installed.
To enter any patch, you must first install all patches with lower patch
numbers than the patch you are entering, beginning with patch number 1,
for a specific software version. If you incorrectly enter the patch
information, you are given the option to review the patch one line at a
time.
Type ^Y or ^C (then RETURN) at any time to abort Code Patch.
Do you wish to continue (y/n) [y] ?
7. Enter Y(es) and follow the onscreen prompts.
8. After the patch is installed, press the controller reset button to restart the controller.