Specifications

Upgrading the Subsystem 3–5
7. Enter option 1. The following display appears:
You have selected the Code Load Utility. This utility is used to load a
new software image into the program card currently inserted in the
controller.
Type ^Y or ^C (then RETURN) at any time to abort code load.
The code image may be loaded using SCSI Write Buffer commands through the
SCSI Host Port, or using KERMIT through the maintenance terminal port.
0: Exit
1: Use the SCSI Host Port
2: Use the Maintenance Terminal Port
Enter option number (0..2) [0] ?
NOTE: Use either the SCSI host port (if operating system supports it) or the maintenance port.
To use the SCSI host port, go to step 8. To use the maintenance port, go to step 10.
8. Enter option 1. The following display appears:
WARNING: proceeding with Controller Code Load will overwrite
the current Controller code image with a new image.
Do you want to continue (y/n) [n]: ?
9. Enter Y(es) and the download starts.
When the download is complete, CLCP writes the new image to the program card and
restarts the controller. This process takes one to three minutes. Go to step 15.
10. Enter option 2. The following display appears:
Perform the following steps before continuing:
* get new image file on serial line host computer
* configure KERMIT with the following parameters:
terminal speed 19200 baud, eight bit, no parity, 1 stop bit
It will take approximately 35 to 45 minutes to perform the code load
operation.
WARNING: proceeding with Controller Code Load will overwrite
the current Controller code image with a new image.
Do you want to continue (y/n) [n]: ?
11. Enter Y(es). The following display appears:
Start KERMIT now...
12. Connect the PC to the controller maintenance port.
13. Configure the KERMIT transfer protocol on the PC to 19200 baud, eight bits, no
parity, and one stop bit.