Specifications

2–28 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
The following display appears:
Do you intend to replace this controller’s cache battery? Y/N
3. Enter N(o). The following menu appears:
FRUTIL Main Menu:
1. Replace or remove a controller or cache module
2. Install a controller or cache module
3. Replace a PVA module
4. Replace an I/O module
5. Exit
Enter choice: 1, 2, 3, 4, or 5 ->
4. Enter option 2. The following menu appears:
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
Enter choice: 1, 2, 3, or 4 ->
5. Enter option 2. The following display appears:
Insert the slot A [
or B
] controller? Y/N
6. Enter Y(es). The following display appears:
Quiescing all device ports. Please wait...
Device Port 1 quiesced.
Device Port 2 quiesced.
Device Port 3 quiesced.
Device Port 4 quiesced.
Device Port 5 quiesced.
Device Port 6 quiesced.
All device ports quiesced.
.
.
.
Insert the controller module, WITH its program card, in slot A [
or B
]
within x minutes, xx seconds.