Specifications

2–18 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
IMPORTANT: Note the following before starting the replacement procedures:
The new controller hardware must be compatible with the remaining controller hardware.
See the product-specific release notes that accompanied the software release for
information regarding hardware compatibility.
The software versions and patch levels must be the same on both controllers.
The new cache module must contain the same memory configuration as the module being
replaced.
Replacing a Controller and Cache Module in a
Dual-Redundant Controller Configuration
Use the following steps in “Removing a Controller and Cache Module in a
Dual-Redundant Controller Configuration” and “Installing a Controller and its Cache
Module in a Dual-Redundant Controller Configuration” to replace a controller and its
cache module.
CAUTION: ESD can easily damage a controller, cache module, or DIMM. Wear a
snug-fitting, grounded ESD wrist strap.
Both cache modules
must
contain the same cache memory configuration.
Removing a Controller and Cache Module in a
Dual-Redundant Controller Configuration
Use the following steps to remove a controller and its cache module.
1. Connect a PC or terminal to the maintenance port of the operational controller.
The controller connected to becomes “this controller;” the controller being removed
becomes the “other controller.”
2. Disable failover with the following command:
SET NOFAILOVER
3. Remove the program card ESD cover and program card from the “other controller.”
Save them in a static-free place for the replacement controller.
4. Start field replacement utility (FRUTIL) with the following command:
RUN FRUTIL