Specifications

Replacement Procedures 2–7
Figure 2–3. Cleaning procedure for GLM
3. Carefully dust out the cavity by rotating the swab tip back and forth one or two times.
4. Repeat step 1 through step 3 for the receiving side of the optical GLM cavity.
Shutting Down the Subsystem
Use the following steps to shut down a subsystem:
1. From a host console, stop all host activity and dismount the logical units in the
subsystem. If using a Microsoft Windows NT platform, shut down the server.
2. Connect a PC or terminal to the maintenance port of one of the controllers in the
subsystem.
3. Shut down the controllers.
In single-controller configurations, shut down “this controller” with the following
command:
SHUTDOWN THIS_CONTROLLER
In dual-redundant controller configurations, shut down the “other controller” first,
then shut down “this controller” with the following commands:
SHUTDOWN OTHER_CONTROLLER
SHUTDOWN THIS_CONTROLLER
GLM
Receptacle
Swab
CXO6531B
1 2 3 4 5 6
1
2
3