Specifications

Replacement Procedures 2–5
3. Configure the terminal emulation software for 9600 baud, 8 data bits, 1 stop bit, and no
parity.
4. Press the Enter or Return key. The command line interface (CLI) prompt appears,
indicating that a local connection was established with the controller.
NOTE: The default data transfer rate of a new controller is 9600 baud. The maximum transfer
rate is 19200. If the current configuration used 19200, use step 5 to establish this rate.
5. Optional step: To increase the data transfer rate to 19200 baud:
a. Set the controller to 19200 baud with one of the following commands:
SET THIS_CONTROLLER TERMINAL SPEED=19200
SET OTHER_CONTROLLER TERMINAL SPEED=19200
b. Configure the PC or terminal for 19200 baud.
When entering CLI commands in a dual-redundant controller configuration, remember
that the controller connected to is “this controller” and the remaining controller is the
“other controller.”
Fibre Channel Optical Cable Cleaning
Instructions
It is essential to clean the Fibre Channel optical cables when replacing the controller to
ensure optimum performance and lifespan of the cable. Use the polyester cloth from the
cleaning kit that came with the cable. Figure 2–2 shows the ferrule on an optical cable.
Figure 2–2. Ferrule on an optical cable
Ferrule
CXO6503B
1