Specifications

Event Reporting: Templates and Codes 5–93
Component Identifier Codes
Component Identifier Codes are embedded in Instance and Last Failure codes. See
“Instance Codes” on page 5–20 and “Last Failure Codes” on page 5–45 for a more
detailed description of the relationship between these codes.
Table 5–20 lists the component identifier codes.
8D It is not safe to present the WWLID to the host because a site failover may have taken place, but cannot
confirm with the remote controller. Perform one of the following repair actions:
Follow repair action 8B.
If a site failover took place, and you don’t plan to perform a future site failback, then delete the
remote copy set on this controller.
8E It is not safe to present the WWLID to the host because a site failover has taken place. Perform one of the
following repair actions:
Perform a site failback.
Delete the remote copy set on this controller.
8F Unable to communicate to a log unit because the unit malfunctioned. Perform the repair actions indicated
in any and all event reports found for that log unit.
Table 5–19 Recommended Repair Action Codes (Sheet 6 of 6)
Code Description
Table 5–20 Component Identifier Codes
Code Description
01 Executive Services
02 Value Added Services
03 Device Services
04 Fault Manager
05 Common Library Routines
06 Dual Universal Asynchronous Receiver/Transmitter Services
07 Failover Control
08 Nonvolatile Parameter Memory Failover Control
09 Facility Lock Manager
0A Integrated Logging Facility