Specifications

5–92 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
69 An unrecoverable fault occurred at the host port. There may be more than one entity attempting to use
the same SCSI ID, or some other bus configuration error, such as improper termination, may exist. If no
host bus configuration problems are found, follow repair action 01.
80 An EMU fault has occurred.
81 The EMU reported terminator power out of range. Replace the indicated I/O module(s).
83 An EMU (Environmental Monitoring Unit) has become unavailable.
This EMU Unit (and associated cabinet) may have been removed from the subsystem; no action is
required.
The cabinet has lost power; restore power to the cabinet.
The EMU-to-EMU communications bus cable has been disconnected or broken; replace or reconnect
the cable to reestablish communications.
The specified EMU is broken; replace the EMU module.
The EMU in cabinet 0 is broken; replace the EMU module.
88 The remote copy set has an online initiator unit and at least one remote NORMAL/NORMALIZING target
member. Failsafe error mode can now be enabled by entering the CLI command SET rc-set-name
ERROR_MODE=FAILSAFE.
89 The remote copy set is inoperative due to a disaster tolerance failsafe locked condition, as a result of the
loss of the local initiator unit or remote NORMAL/NORMALIZING target members while
ERROR_MODE=FAILSAFE was enabled. To clear the failsafe locked condition, enter the CLI command
SET rc-set-name ERROR_MODE=NORMAL.
8A The indicated remote copy set target member was removed for one of the following reasons:
By operator command.
The member malfunctioned. Perform the repair actions indicated in any and all event reports found
for that target member.
8B Unable to communicate to the target member of the remote copy set for one of the following reasons:
The target malfunctioned. Perform the repair actions indicated in any and all event reports found for
that target unit.
The target controller malfunctioned. Perform the repair actions indicated in any and all event reports
found for that target controller.
Malfunction that occurred in the Fibre Channel fabric between the peer controllers.
8C Unable to communicate to an initiator unit of the remote copy set because the unit malfunctioned.
Perform the repair actions indicated in any and all event reports found for that initiator unit.
Table 5–19 Recommended Repair Action Codes (Sheet 5 of 6)
Code Description